AHCAL switchoff procedure
- tab4: Pre_Bias 2 off, then set
- MPODs: switch off HV on all modules
- MPODs: All OFF
AHCAL switchon
- MPOD: LV1 ON, LV2 ON, LV3 on
- labview: Configure x-LDAs
- If troubles with correct acq:
- Expert tab: press STOP acq, then Dump LDAs several times
- configure x-LDAs again until acq get green
- Configure CCC
- Power setup: 5x ON
- Asic power and reset: always on, ON
- Slowcontrol: AT_AG260_TR260_LG1200
- autopopulate
- check if the generated directory exist in one of the layers
- write SC
- Calibration:
- Delay set
- DAC set (be sure, you are in element 0, "first for all" is selected, DAC1 is off
- Switch on HV on MPODS
- Calibration again:
- Set Pre-Bias 2 to ON
- pres set
- Take data tab:
- SET in setup testbeam mode with 1 dummy trigger and spill OFF
- Measurement start
- Chech in the expert tab: occupancy ON. you must see all asics, no white squaresTHen switch
off. - if you see white spots, switch off PRE_Bias 2 and reprogram SC
- Wait for spill ON, dummy triggers 0. Ready to start from EUDAQ!