Current Version: 2023-24
MOD-HV | MODULATOR HV setting |
MAX-OP-VS | LLRF operational maximum VS setting (SP.AMPL.MAX) |
VS | Default operational VS. |
Bold-faced blue MOD HV are increased compared to REDUCED-ENERGY configuration A6 HV updated v19. FE emitter M1.C3 detuned on 25.01.2023 (v24) Reduced v20 after V[e]RG[e] study 11.08.2022 Reduced for radiation. MAX reduced v20 after V[e]RG[e] study 11.08.2022 758 14635 A6 7200 8650 Reduced 35MV after MARWIN studies on 06.04.2022 Increased by 20 MV. FE emitter M1.C3 detuned on 25.01.2023. (v24) Reduced by 20MV on 06.04.2022 due to quench limit Reduced another 15MV on 11.02.2022 (soft quenching --tbc) Reduced by 20MV on 08.04.22. Reduced quench field. Reduced by 20MV on 06.09.22. Reduced quench field. Quench (M2.C5) Updated after V[e]RG[e] studies on 25.02.2022 Updated after V[e]RG[e] studies on 14.11.2022Station MOD HV MAX-OP-VS VS ON-CREST Comment 7200 655 655 A7 7500 680 680 A8 8750 825 825 A9 8200 655 655 A10 8600 800 800 A11 8400 800 800 A12 8200 785 707 Reduced for radiation A13 8700 765 765 A14 7600 635 635 HV updated v19 A15 7450 605 605 HV updated v19 A16 8750 810 729 Reduced for radiation A17 8000 725 725 A18 8600 830 830 A19 8300 710 710 A20 8700 795 795 v21 Reduced MAX VS by 20MV A21 8950 845 761 A22 8400 800 800 A23 8850 842 Reduced for radiation A24 8380 765 765 Reduced 14.11.2022 (M2.C8 quench) A25 8650 635 635 v21 increased HV by +50MV Total 14962 Max Energy 17362 17035 On-crest operation. Assumed 2400 MeV at L2
Station MOD HV MAX-OP-VS VS ON-CREST Comment 655 600 FE emitter M1.C3 detuned on 25.01.2023 (v24) A7 7500 680 665 A8 7900 665 665 A9 8100 640 640 A10 8000 665 665 A11 7200 665 665 A12 7500 665 665 A13 8100 665 665 A14 7600 635 635 A15 7450 605 605 A16 8000 665 665 A17 8000 725 665 A18 8050 665 665 A19 8300 710 665 A20 8000 665 665 A21 8400 665 665 A22 8000 665 665 A23 8100 665 665 A24 7800 665 665 A25 635 635 Total 13205 13090 Max Energy 15605 15490 On-crest operation. Assumed 2400 MeV at L2
Station MAX-VS Limitation Comment A6 655 Radiation A7 680 Quench (M2.C1) Based on 2020 ops experience (21 MV below quench limit) A8 825 Quench (M4.C3) A9 655 Radiation A10 800 Soft Quench (M3.C8) Reduced 35MV due to soft-quenching on 06.04.2022 A11 800 Quench (M1.C3) A12 785 Radiation MARWIN limit (58 MV below quench limit) A13 765 Quench (M4.C3) A14 635 Quench (M3.C7) soft quenching limit A15 605 Quench (M3.C3) Based on 2020 ops experience (68 MV below quench limit). Note since v11 always set to HIGH-VS. A16 810 Quench (M3.C8) Reduced by 25MV due to quench on 21.04.22. Reduced quench field. A17 725 Quench (M4.C8) A18 830 Quench (M1.C1) M3.C4 detuned due to high FE. Updated v14 (2022.02.11) A19 710 Radiation A20 795 Quench (M1.C6) A21 845 Reduced 25 MV on 02.08.2022 (quench limit). A22 800 Quench (M3.C7) A23 842 Radiation M3.C7 detuned on 19.04.22 due to high FE. A24 765 Quench (M2.C8) A25 635 Quench (M2.C3/4/5/8) Total 14962 L3 max energy* 17362 Assumes 2.4 GeV at L2
Detailed history
First measurements with MARWIN indicated ~mSv/h neut rate at A22, which was later identified to be caused by M4.C3. This cavity has now been detuned and the VS configuration modified (loss of 10 MV). Successfully re-established 17.4 GeV operation point, based on re-identification of limits on each RF station. Max SP have been adjusted to reflect these new numbers. HIGH-V config is now set to match the new max SP values. HIGH-V config now supports 16.5 GeV user run with margin for any L3 RF station failure. Reduced-V has now been adjusted to give one spare station margin at 14 GeV beam operation. All stations have been set to 620 MV with the exception of A6 and A9, which are set to 100MV below their radiation-limited maximum voltage. (A19 and A23 are more than 100MV below their radiation-limited max in this configuration). During startup after COVID-19 shutdown. MARWIN recorded 1.2 mGy/h at A6 during the high-voltage operation for BBA. On 26.05.2020 this was discovered to be due to poor M-S phase alignment which actually lead to a higher voltage operation than reported. A6 limit was subsequently checked with MARWIN and re-confirmed. The original 100 uSv/h margin left originally was removed since piezo operation now stabilises the cavity tuning. See Two changes to config: A18 after V[e]RG[e] studies: A18, resulting in detuning of M3.C4 due to excessive radiation (MARWIN neutron limit). A16 change in VS.CAL_SCA after BB-Calibration (1.0 → 1.17) Several stations changed as a result of issues ramping up to >17 GeV for BBA (6-10.04.22) Configurations now include MODULATOR HV and ON-CREST operation. This release also includes a major format change to the page. Note: no VS values have been changed in this release. Set A23 REDUCED-ENERGY MOD HV to current stable setting of 8100 kV (at Vladimir Fogel request; original value of 7600 kV was not achievable.) MOD HV for HIGH ENERGY configuration changed for A6, A14 and A15 (as per instructions from Vladimir Fogel ) Updated (reduced) MAX SP for A11 and A21 following V[e]RG[e] studies: Reduced A20 max VS from 815 to 795 MV (20MV) after V[e]RG[e] study (see logbook entry) Increased A25 HV by +50V to avoid klystron saturation. VS.CAL_SCA modified for A23, A24 (BBCAL data) MAX_OP_VS change: A23: 765 MV → 842 MV (modified 12.09.22) A24: 730 MV → 788 MV (modified 19.09.22)version date modified by Comment 2020-01 06.01.2020 Initial definition of standard High V and Reduced V configurations. High V config is based on operational voltages used during 16.5 GeV run from
9-13.10.2019 with the exception of A24 which was reduced from 855 MV to 700 MV due to a field emission event on 25.10.2019.2020-02 14.01.2020 2020-03 22.01.202 Re-established maximum voltage with current calibration state. Increased A21 from 693 MV to 760 MV. Limiting cavity is M2.C5. Limiter set to 24.8 MV/m (identified hard quench limit). Also increased limiter on M1.C2 by +2 MV/m (limit exceeded but no quench seen). See elog entry: https://ttfinfo.desy.de/elog/XMLlist?file=/XFELelog/data/2020/04/22.01_M/2020-01-22T11:33:22-04.xml&xsl=/elogbook/xsl/elog.xsl&picture=true 2020-04 12.02.2020 Reduced A23 by 40 MV due to excessive neutron rate peak signal on MARWIN. Note this needs to be checked. 2020-05 20.02.2020 2020-06 26.05.2020 2020-07 07.10.2020 2020-08 17.12.2020 Changed A17 max from 730 MV to reflect current setting of 750 MV. This station was limited by klystrons problems. Current max is close to measured quench limited value of 755 MV. 2021-09 08.04.2021 Final update of new limits based on V[e]RG[e] studies during January startup. Several limits have changed, likely to calibration changes. 2021-10 03.05.2021 Based on BBCAL data, the VS.CAL_SCA for A21 was changed from 1.069 to 1.208. The MAXV was scaled accordingly from 770 MV to 870 MV. (Performed on 27.04.2021.) 2021-11 28.06.2021 After adjusting remaining L3 VS.CAL_SCA valued to BBCAL calibrated values on the 20.05.2021. 2021-12 30.08.2021 Increased all voltages for REDUCED-VS, to allow at least 10 degree off-crest operation with one station off beam. Additional margin required by ENERGY SVR. 2021-13 30.09.2021 Excessive radiations appear to originate from M4.C4 which has been detuned. Gradient instabilities seen at ~22MV/m which may be multipacting. Needs to be reviewed. See 2021-09-29 A23 radiation studies for more details. 2022-14 11.02.2022 A18 reduced from 845 MV → 830 MV after V[e]RG[e] study. M1.C1 quenching at 25.0 MV/m (originally recorded at 25.7 MV/m beginning 2021). 2022-15 04.03.2022 A24 further reduced to 730MV after V[e]RG[e] study on 25.02.2022. M2.C8 appears to have further degraded, now quenching at 22.4 MV/m. 2022-16 25.04.2022 2022-17 21.07.2022 2022-18 27.07.2022 2022-19 01.09.2022 2022-20 02.09.2022 2022-21 06.09.2022 2022-22 05.10.2022 2023-23 03.01.2023 Removed ON CREST in HE config for A12, A16, A21 and A23. These stations VS set points are still reduced by 10% from SP.MAX for radiation mitigation. 17.01.2023 Corrected max v for A24 (was changed on 14.11.2022 V[e]RG[e] study). Config designation not updated. See A24 V[e]RG[e] studies 2022.11.07. 2023-24 25.01.2023 Identified strong source of dark current in A6 as M1.C3. See 2023-01-23 A6 Dark Current Studies. Cavity is now detuned operationally. New maximum VS is 655 MV (increased from 635 MV), still limited by radiation (MARWIN neutron rate of 500 uSv/h).